9 Types of Disposable Respirators That Require Fit Testing
1. Overview: Respirator Types
Workers have several kinds of respirators available:
-
Particulate respirators: filter out airborne particles
-
Gas masks: filter out chemicals and gases
-
Airline respirators: use compressed air from a remote source
-
Self-contained breathing apparatus (SCBA): carry their own air supply
This article covers the disposable filtering face-piece respirator, which is discarded entirely when it becomes unsuitable (excessive resistance, absorbent exhaustion, or physical damage). Employers building a program can start with a respiratory protection program that covers selection, fit testing, and H2S training.
2. How Particulate Respirators Work
-
Also called "air-purifying respirators" because they filter particles from the air as you breathe.
-
They protect only against particles, not gases or vapors.
-
Airborne bacteria and viruses are particles, so these respirators can filter them.
3. The Nine Types
Oil-resistance rating (letter)
|
Letter |
Meaning |
|
N |
Not resistant to oil |
|
R |
Somewhat Resistant to oil |
|
P |
Strongly resistant (oil Proof) |
Filter efficiency rating (number)
|
Number |
Minimum filtration (worst-case test, most penetrating particle size) |
|
95 |
At least 95% |
|
99 |
At least 99% |
|
100 |
At least 99.97% (essentially 100%) |
Resulting combinations
-
N-95, N-99, N-100
-
R-95, R-99, R-100
-
P-95, P-99, P-100
An N-95 is just one of these nine. See our comparison of N95 vs. P100 respirators for help choosing.
4. Why Oil Resistance Matters
-
Some industrial oils degrade filter performance.
-
Oil aerosols strip the electrostatic charges between filter layers, which normally act like a magnet to trap particles.
-
Service life limits:
-
R masks: up to 8 hours
-
P masks: up to 40 hours or 30 days, whichever comes first
5. Fit Testing, Training, and Regulation
Why fit matters most
-
A respirator works only if used correctly. The key elements are respirator fit testing and respirator training for each worker in use, maintenance, and care.
-
NIOSH considers all nine types to have similar fit characteristics, so a well-fitting NIOSH-approved respirator matters more than which of the nine it is.
OSHA requirements
The use of respirators is regulated under the OSHA respiratory protection standard. It sets requirements for:
-
Fit-testing, to ensure a proper seal between the respirator and the wearer's face
-
Determining that workers can use respirators safely
-
Training and educating employees
-
Proper maintenance
Note: Fit-testing and the other OSHA-required procedures are absolutely essential to ensure the respirator provides the required protection. Not sure your program meets the standard? Our OSHA compliance services can help.
6. NIOSH Approval and Labeling
NIOSH tests and approves respirators for occupational use. A respirator without the required markings has not been NIOSH-certified, and may be counterfeit or misrepresented. Markings appear on the facepiece, exhalation valve cover, or head straps. You can verify an approval number on the NIOSH Certified Equipment List.
Required markings on each filtering face-piece respirator
-
Manufacturer name (business name, registered trademark, or abbreviation recognized by NIOSH). A private-label entity's name may replace it where applicable.
-
"NIOSH" in block letters or the NIOSH logo
-
NIOSH approval number (e.g., TC-84A-XXXX)
-
Filter series and efficiency level (e.g., N95, P100)
-
Model or part number (e.g., 8577 or 8577A)
Recommended but not required: lot number and/or date of manufacture.
Private-label respirators
The packaging and user instructions must include a special "S" caution and limitation statement:
-
"Marketed by [private label company]"
-
"Produced by [approval holder company]"
This statement does not need to appear on the respirator's exterior surface.